The industrial Ethernet switch adopts high-performance imported switching chip to ensure the stable transmission of large traffic data, and supports 10/100/100M adaptive electrical port; Support -40~85℃ operating temperature, industrial power protection, indicator status display, guide rail/rack installation, fan-less thermal housing design, to achieve real readout, convenient and fast, but also meet the EMC4 level protection, IP40 protection, 6000V lightning protection and other indicators, can adapt to a variety of harsh industrial environment application needs.
● Support 1 100M fiber port + 2 10/100M adaptive copper ports configuration
● Support indicator status display
● Industrial wide temperature design, fanless resonance design
Technical specifications | |
Ethernet Standard | IEEE802.3 (Ethernet), IEEE802.3u (100Base-TX and 100Base-FX) IEEE802.3x (flow control) |
Switch Properties | |
MAC Table | 1K |
Switch Bandwidth | 0.6Gbps |
Packet forwarding rate | 0.45Mpps |
Switching Delay | <5μs |
Interface | |
Ports | Port numbers:3 |
Interface form: 1×9 fixed fiber port (single/multi-mode optional, SC/FC/ST interface optional) or RJ45 100M Tx port | |
Interface rate: 100Base-FX (fiber port), 10/100M adaptive Tx port | |
Power terminal | 5.08mm pitch plug-in terminal |
Communication distance | |
Twisted pair | 100m (standard CAT5/CAT5e cable) |
Multi-mode fiber | 100M multimode: 1310nm, 2km |
Single-mode fiber | 100M single mode: 1310nm, 20/40km; 1550nm, 60/80km |
LED indicator lights | |
Front panel LED | Interface indicator: LINK/ACT; SPEED |
Power status indicator: PWR | |
Power indicator | |
Input voltage | DC12 ~ 48V, DC48V optional AC / DC110V ~ 220V optional |
Full-load Consumption | <5W@full load |
Overload protection | Support |
Reverse protection | Support |
Working Environment | |
Operating Temperature | -40°C~85°C |
Storage temperature | -40°C~85°C |
Ambient Humidity | 5%~95%( non-condensing) |
Physical Characteristics | |
Shell | Aluminum alloy shell, IP40 |
Installation | 35mm din rail-mounted installation |
Dimension | 118mm*86mm*35mm |
Industry standard | |
EMC | EN61000-4-2(ESD), Level 4 EN61000-4-3(RS), Level 4 EN61000-4-4(EFT), Level 4 EN61000-4-5(Surge), Level 4 EN61000-4-6(CS), Level 4 EN61000-4-8, Level 5 |
Impact | IEC60068–2-27 |
Falling | IEC60068-2-32 |
Shock | IEC60068-2-6 |
Warranty | |
Warranty period | 5 Years |
Certification | |
Certification | CE/FCC/RoHS |