PR18-5AO
Installation Flush
Sensing side diameter Ø18mm
Sensing distance 5mm
Hysteresis(distance) Max. 10% of sensing distance
Standard sensing target 18×18×1mm(iron)
Response frequency 20Hz
Indicator Operation indicator (red LED)
Unit weight (packaged weight) ≈ 118 g (≈ 130 g)
Power supply 100 - 240 VAC~ 50 / 60 Hz, operating voltage: 85 - 264 VAC~
Current specification Leakage current: Max. 2.5mA
Control output 5 to 200 mA
Residual voltage Max. 10V
Protection circuit Surge protection circuit
Insulation resistance ≥ 50 MΩ (500 VDC megger)
Insulation type Double insulation or reinforced insulation(mark: , dielectric strength between the measuring input part and the power part: 1kV)
Dielectric strength 2,500 VAC~ 50/60 Hz for 1 minute
Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours
Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times
Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation)
Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation)
Protection structure IP67(IEC standard)
Connection Cable type
Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC)
Material Case/Nut: nickel plated brass, washer: nickel plated iron, sensing side: PBT
Sensing side diameter Ø18mm
Sensing distance 5mm
Hysteresis(distance) Max. 10% of sensing distance
Standard sensing target 18×18×1mm(iron)
Response frequency 20Hz
Indicator Operation indicator (red LED)
Unit weight (packaged weight) ≈ 118 g (≈ 130 g)
Power supply 100 - 240 VAC~ 50 / 60 Hz, operating voltage: 85 - 264 VAC~
Current specification Leakage current: Max. 2.5mA
Control output 5 to 200 mA
Residual voltage Max. 10V
Protection circuit Surge protection circuit
Insulation resistance ≥ 50 MΩ (500 VDC megger)
Insulation type Double insulation or reinforced insulation(mark: , dielectric strength between the measuring input part and the power part: 1kV)
Dielectric strength 2,500 VAC~ 50/60 Hz for 1 minute
Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours
Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times
Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation)
Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation)
Protection structure IP67(IEC standard)
Connection Cable type
Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC)
Material Case/Nut: nickel plated brass, washer: nickel plated iron, sensing side: PBT
4.9
★ ★ ★ ★ ★
12 views
5 star 5 (100%)
4 star 0 (0%)
3 star 0 (0%)
2 star 0 (0%)
1 star 0 (0%)
Reviews
All Reviews(5) Image/Video(0) 5 star(5)
×
0/500
Score Excellent
★ ★ ★ ★ ★ 08/10/2024
High satisfaction with the build and performance
(736)
★ ★ ★ ★ ★ 07/06/2024
Precision engineering
(534)
★ ★ ★ ★ ★ 30/04/2024
The AUTONICS PR18-5AO has been a reliable choice
(668)
★ ★ ★ ★ ★ 08/01/2024
Durability exceeds expectations
(536)
★ ★ ★ ★ ★ 16/12/2023
Quality is exceptional
(880)