TC4S-14R
Size DIN W48×H48mm
Display method 4-digit 7-segment LED
Control method ON/OFF, P, PI, PD, PID
Input specification Thermocouple: K(CA), J(IC), L(IC)
RTD: DPt100Ω, Cu50Ω
Sampling cycle 100ms
Control output Relay (250VAC~ 3A) or SSR drive (12VDC ) [ON/OFF, phase, cycle]
Option output Alarm 1
Power supply 100-240VAC~ 50/60Hz
Display accuracy_RTD •At room temperature(23ºC ± 5ºC):(PV ± 0.5% or ±1ºC, select the higher one) ± 1-digit
•Out of room temperature range:(PV± 0.5% or ±2ºC, select the higher one)± 1-digit
Display accuracy_Thermocouple •At room temperature(23ºC ± 5ºC):(PV ± 0.5% or ±1ºC, select the higher one) ± 1-digit
•Out of room temperature range:(PV± 0.5% or ±2ºC, select the higher one)± 1-digit
Hysteresis(adjustable sensitivity) 1 to 100℃/℉(0.1 to 50.0℃/℉) variable
Proportional band 0.1 to 999.9℃/℉
Integral time 0 to 9999 sec
Derivative time 0 to 9999 sec
Control period 0.5 to 120.0 sec
Manual reset 0.0 to 100.0%
Environment_Ambient temperature -10 to 50℃, storage: -20 to 60℃
Environment_Ambient humidity 35 to 85% RH, storage: 35 to 85% RH
Insulation type Double insulation or reinforced insulation(mark: , dielectric strength between the measuring input part and the power part: AC power 2kV, AC/DC Power 1kV)
Weight Approx. 141g(approx. 94g)
Display method 4-digit 7-segment LED
Control method ON/OFF, P, PI, PD, PID
Input specification Thermocouple: K(CA), J(IC), L(IC)
RTD: DPt100Ω, Cu50Ω
Sampling cycle 100ms
Control output Relay (250VAC~ 3A) or SSR drive (12VDC ) [ON/OFF, phase, cycle]
Option output Alarm 1
Power supply 100-240VAC~ 50/60Hz
Display accuracy_RTD •At room temperature(23ºC ± 5ºC):(PV ± 0.5% or ±1ºC, select the higher one) ± 1-digit
•Out of room temperature range:(PV± 0.5% or ±2ºC, select the higher one)± 1-digit
Display accuracy_Thermocouple •At room temperature(23ºC ± 5ºC):(PV ± 0.5% or ±1ºC, select the higher one) ± 1-digit
•Out of room temperature range:(PV± 0.5% or ±2ºC, select the higher one)± 1-digit
Hysteresis(adjustable sensitivity) 1 to 100℃/℉(0.1 to 50.0℃/℉) variable
Proportional band 0.1 to 999.9℃/℉
Integral time 0 to 9999 sec
Derivative time 0 to 9999 sec
Control period 0.5 to 120.0 sec
Manual reset 0.0 to 100.0%
Environment_Ambient temperature -10 to 50℃, storage: -20 to 60℃
Environment_Ambient humidity 35 to 85% RH, storage: 35 to 85% RH
Insulation type Double insulation or reinforced insulation(mark: , dielectric strength between the measuring input part and the power part: AC power 2kV, AC/DC Power 1kV)
Weight Approx. 141g(approx. 94g)
4.9
★ ★ ★ ★ ★
12 views
5 star 7 (100%)
4 star 0 (0%)
3 star 0 (0%)
2 star 0 (0%)
1 star 0 (0%)
Reviews
All Reviews(7) Image/Video(0) 5 star(7)
×
0/500
Score Excellent
★ ★ ★ ★ ★ 29/10/2024
The precision of this model is top-notch
(625)
★ ★ ★ ★ ★ 28/10/2024
Quality components make a noticeable difference
(728)
★ ★ ★ ★ ★ 10/09/2024
Outstanding build and durability
(933)
★ ★ ★ ★ ★ 26/04/2024
The AUTONICS TC4S-14R is incredibly reliable
(548)
★ ★ ★ ★ ★ 23/04/2024
I've seen cheaper models fail, but this one holds up
(960)
★ ★ ★ ★ ★ 07/04/2024
I've used it for years without any issues
(726)
★ ★ ★ ★ ★ 14/12/2023
High quality materials ensure a longer lifespan
(943)